Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Radiol Imaging Cancer ; 6(2): e230080, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38334471

RESUMO

Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.6%] women) with 29 retroperitoneal tumors treated over 22 MWA procedures. Hydrodissection (0.9% saline with 2% iohexol) was injected in 17 of 22 (77.3%) procedures to protect nontarget anatomy. The primary outcomes evaluated were local tumor progression (LTP) and complication rates. Oncologic outcomes, including overall survival (OS), progression-free survival (PFS), and treatment-free interval (TFI), were examined as secondary outcome measures. Results Median follow-up was 18 months (range = 0.5-113). Hydrodissection was successful in displacing nontarget anatomy in 16 of 17 (94.1%) procedures. The LTP rate was 3.4% (one of 29; 95% CI: 0.1, 17.8) per tumor and 5.3% (one of 19; 95% CI: 0.1, 26.0) per patient. The overall complication rate per patient was 15.8% (three of 19), including two minor complications and one major complication. The OS rate at 1, 2, and 3 years was 81.8%, 81.8%, and 72.7%, respectively, with a median OS estimated at greater than 7 years. There was no evidence of a difference in OS (P = .34) and PFS (P = .56) between patients with renal cell carcinoma (six of 19 [31.6%]) versus other tumors (13 of 19 [68.4%]) and patients treated with no evidence of disease (15 of 22 [68.2%]) versus patients with residual tumors (seven of 22 [31.8%]). Median TFI was 18 months (range = 0.5-108). Conclusion Treatment of retroperitoneal tumors with MWA combined with hydrodissection provided high rates of local control, prolonged systemic therapy-free intervals, and few serious complications. Keywords: Ablation Techniques (ie, Radiofrequency, Thermal, Chemical), Retroperitoneum, Microwave Ablation, Hydrodissection © RSNA, 2024.


Assuntos
Neoplasias Renais , Neoplasias Retroperitoneais , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/radioterapia , Neoplasias Retroperitoneais/cirurgia , Resultado do Tratamento , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia
2.
Acad Radiol ; 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38286723

RESUMO

Radiomics uses advanced mathematical analysis of pixel-level information from radiologic images to extract existing information in traditional imaging algorithms. It is intended to find imaging biomarkers related to the genomics of tumors or disease patterns that improve medical care by advanced detection of tumor response patterns in tumors and to assess prognosis. Radiomics expands the paradigm of medical imaging to help with diagnosis, management of diseases and prognostication, leveraging image features by extracting information that can be used as imaging biomarkers to predict prognosis and response to treatment. Radiogenomics is an emerging area in radiomics that investigates the association between imaging characteristics and gene expression profiles. There are an increasing number of research publications using different radiomics approaches without a clear consensus on which method works best. We aim to describe the workflow of radiomics along with a guide of what to expect when starting a radiomics-based research project.

3.
Adv Radiat Oncol ; 8(5): 101241, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37250282

RESUMO

Purpose: The recently reported FLAME trial demonstrated a biochemical disease-free survival benefit to using a focal intraprostatic boost to multiparametric magnetic resonance imaging (mpMRI)-identified lesions in men with localized prostate cancer treated with definitive radiation therapy. Prostate-specific membrane antigen (PSMA)-directed positron emission tomography (PET) may identify additional areas of disease. In this work, we investigated using both PSMA PET and mpMRI in planning focal intraprostatic boosts using stereotactic body radiation therapy (SBRT). Methods and Materials: We evaluated a cohort of patients (n = 13) with localized prostate cancer who were imaged with 2-(3-(1-carboxy-5-[(6-[18F]fluoro-pyridine-2-carbonyl)-amino]-pentyl)-ureido)-pentanedioic acid (18F-DCFPyL) PET/MRI on a prospective imaging trial before undergoing definitive therapy. The number of lesions concordant (overlapping) and discordant (no overlap) on PET and MRI was assessed. Overlap between concordant lesions was evaluated using the Dice and Jaccard similarity coefficients. Prostate SBRT plans were created fusing the PET/MRI imaging to computed tomography scans acquired the same day. Plans were created using only MRI-identified lesions, only PET-identified lesions, and the combined PET/MRI lesions. Coverage of the intraprostatic lesions and doses to the rectum and urethra were assessed for each of these plans. Results: The majority of lesions (21/39, 53.8%) were discordant between MRI and PET, with more lesions seen by PET alone (12) than MRI alone (9). Of lesions that were concordant between PET and MRI, there were still areas that did not overlap between scans (average Dice coefficient, 0.34). Prostate SBRT planning using all lesions to define a focal intraprostatic boost provided the best coverage of all lesions without compromising constraints on the rectum and urethra. Conclusions: Using both mpMRI and PSMA-directed PET may better identify all areas of gross disease within the prostate. Using both imaging modalities could improve the planning of focal intraprostatic boosts.

4.
PLoS One ; 18(4): e0283830, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023049

RESUMO

Prostate specific membrane antigen (PSMA)-based radiotracers have shown promise for prostate cancer assessment. Evaluation of quantitative variability and establishment of reference standards are important for optimal clinical and research utility. This work evaluates the variability of PSMA-based [18F]DCFPyL (PyL) PET quantitative reference standards. Consecutive eligible patients with biochemically recurrent prostate cancer were recruited for study participation from August 2016-October 2017. After PyL tracer injection, whole body PET/CT (wbPET/CT) was obtained with subsequent whole body PET/MR (wbPET/MR). Two readers independently created regions of interest (ROIs) including a 40% standardized uptake value (SUV) threshold ROI of the whole right parotid gland and separate spherical ROIs in the superior, mid, and inferior gland. Additional liver (right lobe) and blood pool spherical ROIs were defined. Bland-Altman analysis, including limits of agreement (LOA), as well as interquartile range (IQR) and coefficient of variance (CoV) was used. Twelve patients with prostate cancer were recruited (mean age, 61.8 yrs; range 54-72 years). One patient did not have wbPET/MR and was excluded. There was minimal inter-reader SUVmean variability (bias±LOA) for blood pool (-0.13±0.42; 0.01±0.41), liver (-0.55±0.82; -0.22±1.3), or whole parotid gland (-0.05±0.31; 0.08±0.24) for wbPET/CT and wbPET/MR, respectively. Greater inter-reader variability for the 1-cm parotid gland ROIs was present, for both wbPET/CT and wbPET/MR. Comparing wbPET/CT to the subsequently acquired wbPET/MR, blood pool had a slight decrease in SUVmean. The liver as well as parotid gland showed a slight increase in activity although the absolute bias only ranged from 0.45-1.28. The magnitude of inter-subject variability was higher for the parotid gland regardless of modality or reader. In conclusion, liver, blood pool, and whole parotid gland quantitation show promise as reliable reference normal organs for clinical/research PET applications. Variability with 1-cm parotid ROIs may limit its use.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Fígado/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Padrões de Referência
5.
Magn Reson Imaging ; 93: 108-114, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35944809

RESUMO

OBJECTIVES: To prospectively compare image quality and apparent diffusion coefficient (ADC) quantification for reduced field-of-view (rFOV)- and multi-shot echo-planar imaging (msEPI)-based diffusion weighted imaging (DWI), using single-shot echo-planar-imaging (ssEPI) DWI as the reference. METHODS: Under IRB approval and after informed consent, msEPI, rFOV, and ssEPI DWI acquisitions were prospectively added to clinical prostate MRI exams at 3.0 T. Image distortion was quantitatively evaluated by root-mean-squared displacement (dr.m.s.). Histogram-based quantitative ADC parameters were compared in a sub-set of patients for proven sites of prostate cancer and matched non-cancerous prostate. Three radiologists also independently evaluated the DWI sequences for subjective image quality and distortion/artifact on a 5-point Likert scale. RESULTS: Twenty-five patients were included (15 with proven sites of cancer). Average dr.m.s. demonstrated a small but statistically significant reduction in distortion for both rFOV and msEPI relative to ssEPI. Quantitative ADC parameters for prostate tumors demonstrated no significant difference across the 3 DWI acquisitions and each acquisition demonstrated a statistically significant decrease in mean ADC for tumor compared to normal prostate. Qualitative reader assessment demonstrated favorable image quality for rFOV and msEPI, more notable for msEPI. CONCLUSIONS: rFOV and msEPI DWI techniques achieved reduction in image distortion, improvement in image quality, and maintained reproducible ADC quantification compared to the standard ssEPI.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
6.
Abdom Radiol (NY) ; 47(8): 2674-2680, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35278110

RESUMO

OBJECTIVE: To evaluate the effect of intra-procedural contrast-enhanced CT (CECT) and same-session repeat ablation (SSRA) on primary efficacy, the complete eradication of tumor after the first ablation session as confirmed on first imaging follow-up, of clinically localized T1a (cT1a) renal cell carcinoma (RCC). METHODS: 398 consecutive patients with cT1a RCC were treated with cryoablation between 10/2003 and 12/2017, radiofrequency (RFA) or microwave ablation (MWA) between 1/2010 and 12/2017. SSRA was performed for residual tumor identified on intra-procedural CECT. Kruskal-Wallis and Pearson's chi-squared tests were performed to assess differences in continuous and categorical variables, respectively. Multivariate linear regression was used to determine predictors for primary efficacy and decline in estimated glomerular filtration rate. RESULTS: 347 consecutive patients (231 M, mean age 67.5 ± 9.1 years) were included. Median tumor diameter was smaller [2.5 vs 2.7 vs 2.6 (p = 0.03)] and RENAL Nephrometry Score (NS) was lower [6 vs 7 vs 7 (p = 0.009] for MWA compared to the RFA and cryoablation cohorts, respectively. Primary efficacy was higher in the MWA cohort [99.4% (170/171)] compared to the RFA [91.4% (85/93)] and cryoablation [92.8% (77/83)] cohorts (p = 0.001). Microwave ablation and SSRA was associated with higher primary efficacy on multivariate linear regression (p = 0.01-0.03). CONCLUSION: MWA augmented by SSRA, when residual tumor is identified on intra-procedural CECT, may improve primary efficacy for cT1a RCC.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Neoplasia Residual , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Eur Radiol ; 32(8): 5458-5467, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35307745

RESUMO

OBJECTIVES: 3D chemical shift-encoded (CSE) MRI enables accurate and precise quantification of proton density fat fraction (PDFF) and R2*, biomarkers of hepatic fat and iron deposition. Unfortunately, 3D CSE-MRI requires reliable breath-holding. Free-breathing 2D CSE-MRI with sequential radiofrequency excitation is a motion-robust alternative but suffers from low signal-to-noise-ratio (SNR). To overcome this limitation, this work explores the combination of flip angle-modulated (FAM) 2D CSE imaging with a non-local means (NLM) motion-corrected averaging technique. METHODS: In this prospective study, 35 healthy subjects (27 children/8 adults) were imaged on a 3T MRI-system. Multi-echo 3D CSE ("3D") and 2D CSE FAM ("FAM") images were acquired during breath-hold and free-breathing, respectively, to obtain PDFF and R2* maps of the liver. Multi-repetition FAM was postprocessed with direct averaging (DA)- and NLM-based averaging and compared to 3D CSE using Bland-Altmann and regression analysis. Image qualities of PDFF and R2* maps were reviewed by two radiologists using a Likert-like scale (score 1-5, 5 = best). RESULTS: Compared to 3D CSE, multi-repetition FAM-NLM showed excellent agreement (regression slope = 1.0, R2 = 0.996) for PDFF and good agreement (regression slope 1.08-1.15, R2 ≥ 0.899) for R2*. Further, multi-repetition FAM-NLM PDFF and R2* maps had fewer artifacts (score 3.8 vs. 3.2, p < 0.0001 for PDFF; score 3.2 vs. 2.6, p < 0.001 for R2*) and better overall image quality (score 4.0 vs. 3.5, p < 0.0001 for PDFF; score 3.4 vs. 2.7, p < 0.0001 for R2*). CONCLUSIONS: Free-breathing FAM-NLM provides superior image quality of the liver compared to the conventional breath-hold 3D CSE-MRI, while minimizing bias for PDFF and R2* quantification. KEY POINTS: • 2D CSE FAM-NLM is a free-breathing method for liver fat and iron quantification and viable alternative for patients unable to hold their breath. • 2D CSE FAM-NLM is a feasible alternative to breath-hold 3D CSE methods, with low bias in proton density fat fraction (PDFF) and no clinically significant bias in R2*. • Quantitatively, multiple repetitions in 2D CSE FAM-NLM lead to improved SNR.


Assuntos
Interpretação de Imagem Assistida por Computador , Prótons , Adulto , Criança , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Ferro , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Abdom Radiol (NY) ; 47(6): 2230-2237, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35238963

RESUMO

OBJECTIVE: To compare image quality and radiation dose between single-bolus 2-phase and split-bolus 1-phase CT Urography (CTU) performed immediately after microwave ablation (MWA) of clinically localized T1 (cT1) RCC. METHODS: Forty-two consecutive patients (30 M, mean age 67.5 ± 9.0) with cT1 RCC were treated with MWA from 7/2013 to 12/2013 at two academic quaternary-care institutions. Renal parenchymal enhancement, collecting system opacification and distention and size-specific dose estimate (SSDE) were quantified and image quality subjectively assessed on single-bolus 2-phase versus split-bolus 1-phase CTU. Kruskal-Wallis and Pearson's Chi-squared tests were performed to assess differences in continuous and categorical variables, respectively. Two-sample T test with equal variances was used to determine differences in quantitative and qualitative image data. RESULTS: Median tumor diameter was larger [2.9 cm (IQR 1.7-5.3) vs 3.6 cm (IQR 1.7-5.7), p = 0.01] in the split-bolus cohort. Mean abdominal girth (p = 0.20) was similar. Number of antennas used and unenhanced CTs obtained before and during MWA were similar (p = 0.11-0.32). Renal pelvis opacification (2.5 vs 3.5, p < 0.001) and distention (4 mm vs 8 mm, p < 0.001) were improved and renal enhancement (Right: 127 HU vs 177 HU, p = 0.001; Left: 124 HU vs 185 HU, p < 0.001) was higher for the split-bolus CTU. Image quality was superior for split-bolus CTU (3.2 vs 4.0, p = 0.004). Mean SSDE for the split-bolus CTU was significantly lower [163.9 mGy (SD ± 73.9) vs 36.3 mGy (SD ± 7.7), p < 0.001]. CONCLUSION: Split-bolus CTU immediately after MWA of cT1 RCC offers higher image quality, improved opacification/distention of the collecting system and renal parenchymal enhancement at a lower radiation dose.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Exposição à Radiação , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Meios de Contraste , Feminino , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos
9.
Abdom Radiol (NY) ; 47(8): 2658-2668, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34731282

RESUMO

PURPOSE: To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. METHODS: 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected. RESULTS: Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series. CONCLUSION: Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Animais , Meios de Contraste , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Doses de Radiação , Suínos , Tomografia Computadorizada por Raios X/métodos
10.
Abdom Radiol (NY) ; 47(8): 2647-2657, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34687328

RESUMO

PURPOSE: To evaluate the efficacy of percutaneous biopsy for diagnosing intrahepatic cholangiocarcinoma (IHCCA). METHODS: Retrospective review of biopsy and pathology databases from 2006 to 2019 yielded 112 patients (54F/58 M; mean age, 62.9 years; 27 cirrhotic) with IHCCA who underwent percutaneous biopsy. Data regarding the lesion, biopsy procedure technique, and diagnostic yield were collected. If biopsy was non-diagnostic or discordant with imaging, details of repeat biopsy or resection/explant were gathered. A control group of 100 consecutive patients (56F/44 M; mean age, 63 years, 5 cirrhotic) with focal liver lesions > 1 cm was similarly assessed. RESULTS: Mean IHCCA lesion size was 6.1 ± 3.6 cm, with dominant lesion sampled in 78% (vs. satellite in 22%). 95% (n = 106) were US guided and 96% were core biopsies (n = 108), typically 18G (n = 102, 91%), median 2 passes. 18 patients (16%) had discordant/ambiguous pathology results requiring repeat biopsy, with two patients requiring 3-4 total attempts. A 4.4% minor complication rate was seen. Mean time from initial biopsy to final diagnosis was 60 ± 120 days. Control group had mean lesion size of 2.9 ± 2.5 cm and showed a non-diagnostic rate of 3.3%, both significantly lower than that seen with CCA, with average time to diagnosis of 21 ± 28.8 days (p = 0.002, p = 0.001). CONCLUSION: IHCCA is associated with lower diagnostic yield at initial percutaneous biopsy, despite larger target lesion size. If a suspicious lesion yields a biopsy result discordant with imaging, the radiologist should recommend prompt repeat biopsy to prevent delay in diagnosis.


Assuntos
Colangiocarcinoma , Tomografia Computadorizada por Raios X , Biópsia com Agulha de Grande Calibre , Colangiocarcinoma/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem/métodos , Cirrose Hepática/etiologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
11.
Am J Transl Res ; 13(10): 12107-12113, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34786148

RESUMO

In this retrospective study we compared the PCa detection rates between combined (combined MRI/US fusion targeted biopsy with concurrent standard biopsy) and standard systemic, combined and targeted (component), and targeted (component) and concurrent standard (component) biopsies. DESIGN: Two cohorts, totaling 735 cases, were selected from the University of Wisconsin Pathology archive. 390 cases (cohort 1) were combined biopsies from 2017-2020 and 345 cases (cohort 2) were part of the standard US-guided systematic biopsies from the same period. PCa was stratified into three categories: low, intermediate, and high risks. RESULTS: We found that combined biopsy was significantly better than the standard biopsy in detection of PCa (65.4% vs. 51.6%, P<0.01) and intermediate-risk PCa (18.7% vs. 10.4%, P=0.05) but only slightly better at detecting high-risk PCa (26.7% vs. 23.5%, P=0.32). Further examining the biopsy results in cohort 1, we found that combined biopsy was superior to targeted biopsy (65.4% vs. 56.9%, P=0.02) or concurrent standard biopsy (65.4% vs. 52.1%, P=0.0002) in PCa detection. Combined biopsy detected significantly more high-risk PCa than concurrent standard biopsy (26.7% vs. 17.4, P=0.002), but the difference in detecting high-risk PCa between combined and targeted biopsies was not significant (26.7% vs. 22.1%, P=0.133). Similarly, the differences in detecting PCa and high-risk PCa between targeted and concurrent standard biopsies were not significant (56.9% vs. 52.1%, P=0.172 and 22.1% vs. 17.4, P=0.133, respectively). Both targeted and concurrent standard biopsies missed PCa of each risk level. CONCLUSION: Combined MRI/US fusion targeted plus standard prostate biopsy is a superior technique for the detection of PCa and clinically significant PCa.

12.
J Endourol ; 35(S2): S33-S37, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34499558

RESUMO

Management options for small renal masses include active surveillance, partial nephrectomy, radical nephrectomy, and thermal ablation. For tumors typically ≤3 cm in size, thermal ablation is a good option for those desiring an alternative to surgery or active surveillance, especially in patients who are considered high surgical risk. We favor microwave ablation because of the more rapid heating, higher temperatures that overcome the heat sink effect of vessels, reproducible cell kill, and a highly visible ablation zone formed by water vapor that corresponds well to the zone of necrosis. For central tumors, we favor cryoablation because of the slower formation of the ablation zone and less likelihood of damage to the collecting system. With microwaves, it is important to monitor the ablation zone in real time (ultrasound is the best modality for this purpose), avoid direct punctures of the collecting system, and to place probes tangential to the collecting system to avoid burning open a persistent tract between the urothelium and extrarenal spaces or causing strictures. The surgical steps described in this video cover our use of high-frequency jet ventilation with general anesthesia to minimize organ motion, initial imaging and targeting, probe insertion, hydrodissection (a technique that enables displacement of adjacent structures), the ablation itself, and finally our dressing. Postoperative cares typically consist of observation with a same-day discharge or an overnight stay. Follow-up includes a magnetic resonance imaging abdomen with and without contrast, chest X-ray, and laboratories (basic metabolic panel, complete blood count, and C-reactive protein) 6 months postablation. Overall, percutaneous microwave ablation is an effective and safe treatment option for renal cell carcinoma in both T1a and T1b tumors in selected patients with multiple studies showing excellent oncologic outcomes when compared with partial and radical nephrectomy.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Nefrectomia , Resultado do Tratamento
13.
J Gastrointest Oncol ; 12(4): 1454-1469, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34532102

RESUMO

BACKGROUND: The purpose of this study is to evaluate the safety and intermediate-term efficacy of percutaneous microwave (MW) ablation for the treatment of colorectal liver metastases (CRLM) at a single institution. METHODS: A retrospective review was performed of all CRLM treated with MW ablation from 3/2011 to 7/2020 (102 tumors; 72 procedures; 57 patients). Mean age was 60 years (range, 36-88) and mean tumor size was 1.8 cm (range, 0.5-5.0 cm). The patient population included 19 patients with extra-hepatic disease. Chemotherapy (pre- and/or post-ablation) was given in 98% of patients. Forty-five sessions were preceded by other focal CRLM treatments including resection, ablation, radiation, and radioembolization. Kaplan-Meier curves were used to estimate local tumor progression-free survival (LTPFS), disease-free survival (DFS), and overall survival (OS) and multivariate analysis (Cox Proportional Hazards model) was used to test predictors of OS. RESULTS: Technical success (complete ablation) was 100% and median follow-up was 42 months (range, 1-112). There was a 4% major complication rate and an overall complication rate of 8%. Local tumor progression (LTP) rate during the entire study period was 4/98 (4%), in which 2 were retreated with MW ablation for a secondary LTP-rate of 2%. LTP-free survival at 1, 3, and 5 years was 93%, 58%, and 39% and median LTP-free survival was 48 months. OS at 1, 3, and 5 years was 96%, 66%, 47% and median OS was 52 months. There were no statistically significant predictors of OS. CONCLUSIONS: MW ablation of hepatic colorectal liver metastases appears safe with excellent local tumor control and prolonged survival compared to historical controls in selected patients. Further comparative studies with other local treatment strategies appear indicated.

14.
Ultrasound Med Biol ; 47(8): 2138-2156, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34011451

RESUMO

Liver cancer is a leading cause of cancer-related deaths; however, primary treatment options such as surgical resection and liver transplant may not be viable for many patients. Minimally invasive image-guided microwave ablation (MWA) provides a locally effective treatment option for these patients with an impact comparable to that of surgery for both cancer-specific and overall survival. MWA efficacy is correlated with accurate image guidance; however, conventional modalities such as B-mode ultrasound and computed tomography have limitations. Alternatively, ultrasound elastography has been used to demarcate post-ablation zones, yet has limitations for pre-ablation visualization because of variability in strain contrast between cancer types. This study attempted to characterize both pre-ablation tumors and post-ablation zones using electrode displacement elastography (EDE) for 13 patients with hepatocellular carcinoma or liver metastasis. Typically, MWA ablation margins of 0.5-1.0 cm are desired, which are strongly correlated with treatment efficacy. Our results revealed an average estimated ablation margin inner quartile range of 0.54-1.21 cm with a median value of 0.84 cm. These treatment margins lie within or above the targeted ablative margin, indicating the potential to use EDE for differentiating index tumors and ablated zones during clinical ablations. We also obtained a high correlation between corresponding segmented cross-sectional areas from contrast-enhanced computed tomography, the current clinical gold standard, when compared with EDE strain images, with r2 values of 0.97 and 0.98 for pre- and post-ablation regions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Técnicas de Imagem por Elasticidade/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Ablação por Radiofrequência , Adulto , Idoso , Idoso de 80 Anos ou mais , Correlação de Dados , Técnicas de Imagem por Elasticidade/instrumentação , Eletrodos , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório
15.
Eur Radiol ; 31(8): 5490-5497, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33492471

RESUMO

OBJECTIVE: To evaluate the effect of intravenous iodinated contrast on estimated glomerular filtration rate (eGFR) when administered immediately after thermal ablation of clinically localized T1a (cT1a) renal cell carcinoma (RCC). METHODS: This HIPAA-compliant, dual-center retrospective study was performed under a waiver of informed consent. Three hundred forty-two consecutive patients with cT1a biopsy-proven RCC were treated with percutaneous ablation between January 2010 and December 2017. Immediate post-ablation contrast-enhanced CT was the routine standard of care at one institution (contrast group), but not the other (control group). One-month pre- and 6-month post-ablation eGFR were compared using the Wilcoxon signed-rank test or the Kruskal-Wallis test. Multivariate linear regression was used to determine the effect of contrast on eGFR. A 1:1 propensity score matching was performed for all patients with a logistic model using patient, tumor, and procedural covariates. RESULTS: In total, 246 patients (158 M; median age 69 years, IQR 62-74) were included. Median tumor diameter (2.4 vs 2.5, p = 0.23) and RENAL nephrometry scores (6 vs 6, p = 0.92), surrogates for ablation zone size, were similar. Baseline kidney function was similar for the control and contrast groups, respectively (median eGFR: 70 vs 74 mL/min/1.73 m2, p = 0.29). There was an expected mild decline in eGFR after ablation (control: 70 vs 60 mL/min/1.73 m2, p < 0.001; contrast: 75 vs 71 mL/min/1.73 m2, p = 0.001). Intravenous iodinated contrast was not associated with a decline in eGFR on multivariate linear regression (1.91, 95% CI - 3.43-7.24, p = 0.46) or 1:1 propensity score-matched model (- 0.33, 95% CI - 6.81-6.15, p = 0.92). CONCLUSION: Intravenous iodinated contrast administered during ablation of cT1a RCC has no effect on eGFR. KEY POINTS: • Intravenous iodinated contrast administered during thermal ablation of clinically localized T1a renal cell carcinoma has no effect on kidney function. • Thermal ablation of clinically localized T1a renal cell carcinoma results in a mild decline in kidney function. • A decline in kidney function is similar for radiofrequency and microwave ablation of clinically localized T1a renal cell carcinoma.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Meios de Contraste , Taxa de Filtração Glomerular , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Micro-Ondas , Estudos Retrospectivos , Resultado do Tratamento
16.
Urology ; 146: 152-157, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32781079

RESUMO

OBJECTIVE: To evaluate postoperative recurrence patterns for high-risk nonmetastatic renal cell carcinoma (RCC) and to identify prognostic factors associated with site-specific metastatic recurrence using a multi-institutional contemporary cohort. METHODS: Data for nonmetastatic ≥pT3a RCC patients treated with surgery at 4 independent centers was analyzed. Initial recurrence locations were identified, and imaging templates were defined by anatomic landmarks using radiologic definitions. Prognostic factors for site specific recurrence were evaluated with univariate and multivariable analyses. RESULTS: A total of 1057 patients were treated surgically for ≥pT3a RCC. Initial recurrence location was in a single site for 160 (59.3%) patients and at multiple locations in 110 (41.7%) patients. The most common sites of metastatic recurrence were lung (144/270, 53.3%), liver (54/270, 20.0%), and bone (48/270, 17.8%). Recurrence was identified in 52 of 270 (19.3%) patients outside the chest/abdomen template, most commonly in the pelvis (25/270, 9.3%). Bone and brain metastases were the most common organs for metastases outside chest/abdomen. Patients with tumor diameter >10 cm and grade 4 were more likely to recur in the bone (HR 3.61, P <.001) and brain (HR 16.5, P <.001). CONCLUSION: Metastatic progression outside chest/abdomen imaging templates was present in 1 of 5 high risk patients at initial metastatic RCC diagnosis, most commonly in the pelvis. Patients with large (>10 cm) tumors and grade 4 histology are at highest risk for bone and brain metastases.


Assuntos
Neoplasias Ósseas/epidemiologia , Neoplasias Encefálicas/epidemiologia , Carcinoma de Células Renais/epidemiologia , Neoplasias Renais/cirurgia , Nefrectomia/efeitos adversos , Adulto , Idoso , Neoplasias Ósseas/secundário , Neoplasias Encefálicas/secundário , Carcinoma de Células Renais/secundário , Carcinoma de Células Renais/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Neoplasias Renais/mortalidade , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco/estatística & dados numéricos , Fatores de Risco
17.
Abdom Radiol (NY) ; 45(9): 2810-2824, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32715335

RESUMO

OBJECTIVE: To describe the CT and MR imaging findings after microwave ablation of clinical stage 1 renal cell carcinoma (RCC). METHODS: This single-center retrospective study was performed under a waiver of informed consent. 49 patients (38 M/11F, mean age 66 ± 9.0) with 52 cT1a RCC and 19 patients (10M/9F, mean age 67 ± 9.7) with 19 cT1b RCC were treated with percutaneous microwave ablation between January 2012 and June 2014. The size and volume of the RCC and ablation zone were measured and the kidney, ablation zones and retroperitoneum were assessed at immediate post-procedure CT and surveillance CT and MRI. RESULTS: Median imaging follow-up was 18 months (IQR 12-28). Ablation zones were heterogeneously hyperintense on T1W and hypointense on T2W MRI and hyperdense at CT. Thin peripheral, but no internal enhancement after contrast administration signified successful ablation zones. Ablation zones decreased in size, but did not resolve during surveillance. Immediate post-procedure subcapsular gas and hematoma (5/71, 7%) resolved prior to first follow-up. Focal, enhancing soft tissue within the ablation zone, invariably along the renal margin, signified local recurrence. Local recurrence rates were higher for T1b (2/19, 11%) compared to T1a (1/52, 2%). Urinomas (4/71, 6%) decreased in size and resolved during surveillance. Retroperitoneal fat necrosis (6/71, 9%), with opposed-phase loss of T1W MRI signal, was confirmed at histology after percutaneous biopsy. CONCLUSION: CT and MR imaging features after microwave ablation of renal cell carcinoma are predictable and reliably demonstrate treatment success, early and delayed complications, and local recurrences that can guide patient management.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Imageamento por Ressonância Magnética , Micro-Ondas , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Cardiovasc Intervent Radiol ; 43(9): 1384-1391, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32529338

RESUMO

PURPOSE: Evaluate the safety and efficacy of adrenal microwave ablation performed with continuous intra-arterial blood pressure monitoring (IABPM) and without alpha-adrenergic blockade (AAB) as pretreatment. MATERIAL AND METHODS: A single-center, retrospective review of all percutaneous adrenal microwave ablation performed between 2011 and 2018. Microwave ablation was completed on 11 patients, with a total of 15 adrenal tumors with a mean size of 3.3 cm (1.4-6.9 cm) treated metastatic RCC, HCC, esophageal carcinoma, adrenal adenoma. Cases were performed without prior AAB, but with continuous IABPM and rapid intervention using short-acting antihypertensive medications. RESULTS: There were no post-procedural episodes of hypertension, no neurological or cardiovascular complications, and no SIR moderate or worse adverse event complications. Mean intraprocedural maximum systolic blood pressure (SBP) was 211 mmHg (range: 132-288), with an average increase in SBP of 100 mmHg (range: 23-180). A hypertensive crisis (SBP ≥ 180 and/or DBP ≥ 120) occurred in 9 of the 15 procedures (60%) with a mean length of 3.0 min (range: 1-12). The technical success rate was 100% (15/15 procedures). The mean follow-up time was 2.4 years (range: 0.9-7.7 years), with primary and secondary efficacy rates of 77% and 87%, respectively, and an overall survival of 82%. CONCLUSION: In this single-center retrospective study, microwave ablation of adrenal tumors without AAB was safe and effective when performed with continuous arterial line monitoring of vital signs and the use of short-acting, rapid-onset antihypertensive medications. LEVEL OF EVIDENCE: Level 4, Case Series.


Assuntos
Técnicas de Ablação/métodos , Neoplasias das Glândulas Suprarrenais/terapia , Antagonistas Adrenérgicos alfa/uso terapêutico , Pressão Arterial/fisiologia , Determinação da Pressão Arterial/métodos , Micro-Ondas/uso terapêutico , Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
19.
Eur Radiol ; 30(6): 3236-3244, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32064561

RESUMO

OBJECTIVES: Conventional spin-echo (SE) DWI leads to a fundamental trade-off depending on the b value: high b value provides better lesion contrast-to-noise ratio (CNR) by sacrificing signal-to-noise ratio (SNR), image quality, and quantitative reliability. A stimulated-echo (STE) DWI acquisition is evaluated for high-CNR imaging of prostate cancer while maintaining SNR and reliable apparent diffusion coefficient (ADC) mapping. METHODS: In this prospective, IRB-approved study, 27 patients with suspected prostate cancer (PCa) were scanned with three DWI sequences (SE b = 800 s/mm2, SE b = 1500 s/mm2, and STE b = 800 s/mm2) after informed consent was obtained. ROIs were drawn on biopsy-confirmed cancer and non-cancerous tissue to perform quantitative SNR, CNR, and ADC measurements. Qualitative metrics (SNR, CNR, and overall image quality) were evaluated by three experienced radiologists. Metrics were compared pairwise between the three acquisitions using a t test (quantitative metrics) and Wilcoxon rank test (qualitative metrics). RESULTS: Quantitative measurements showed that STE DWI at b = 800 s/mm2 has significantly better SNR compared to SE DWI at b = 1500 s/mm2 (p < 0.0001) and comparable CNR to high-b value SE DWI at b = 1500 s/mm2 (p < 0.05) in the peripheral zone. Qualitative assessment showed preference to STE b = 800 s/mm2 in SNR and SE b = 1500 s/mm2 in CNR. The overall image quality and lesion detectability among most readers showed no significant preference between STE b = 800 s/mm2 and SE b = 1500 s/mm2. Further, STE DWI had similar ADC contrast between lesion and normal tissue as SE DWI at b = 800 s/mm2 (p = 0.90). CONCLUSION: STE DWI has the potential to provide high-SNR, high-CNR imaging of prostate cancer while also enabling reliable ADC mapping. KEY POINTS: • Quantitative analysis showed that STE DWI at b = 800 s/mm2is able to achieve simultaneously high CNR, high SNR, and reliable ADC mapping, compared to SE b = 800 s/mm2and SE b = 1500 s/mm2. • Qualitative assessment by three readers showed that STE DWI at b = 800 s/mm2has significantly higher SNR than SE b = 1500 s/mm2. No preference between SE b = 1500 s/mm2and STE b = 800 s/mm2was determined in terms of CNR with no missed lesions were found in both acquisitions. • A single STE DWI acquisition at moderate b value (800-1000 s/mm2) may provide sufficient image quality and quantitative reliability for prostate cancer imaging within a shorter scan time, in place of two DWI acquisitions (one with moderate b value and one with high b value).


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
Urology ; 135: 88-94, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31585198

RESUMO

OBJECTIVE: To compare perioperative and oncologic outcomes for patients with clinical T1b renal cell carcinoma following treatment with microwave ablation (MW), partial nephrectomy (PN), or radical nephrectomy (RN). METHODS: Comprehensive clinical and pathologic data were collected for nonmetastatic renal cell carcinoma patients with cT1b tumors following MW, PN, or RN from 2000 to 2018. Local recurrence-free, metastasis-free, cancer-specific and overall survival were estimated using Kaplan-Meier method. Prognostic factors for complications and survival were determined using logistic regression and Cox hazard models, respectively. RESULTS: A total of 325 patients (40 MW, 74 PN, and 211 RN) were identified. Patients treated with MW were older with higher Charlson comorbidity indices compared to surgical patients. Median length of hospitalization was shorter for MW compared to surgical patients (1 day vs 4 days, P <.0001). Post-treatment estimated glomerular filtration rate decreased by median 4.5% for MW compared to 3.2% for PN (P = .58) and 29% for RN (P <.001). Median follow-up was 34, 35, and 49 months following MW, PN, and RN, respectively. Estimated 5-year local recurrence-free survival was 94.5% for MW vs 97.9% for PN (P = .34) and 99.2% for RN (P = .02). Two patients recurred after MW and underwent repeat ablation without subsequent recurrence. No difference in 5-year metastasis-free survival or cancer-specific survival was found among MW, PN, or RN. Four (10%) MW patients had high-grade complication. Only prior abdominal surgery predicted high-grade complication (OR 6.29, P = .017). CONCLUSION: Microwave ablation is a feasible alternative to surgery in select comorbid patients with clinical T1b renal cell carcinoma.


Assuntos
Carcinoma de Células Renais/cirurgia , Neoplasias Renais/cirurgia , Recidiva Local de Neoplasia/cirurgia , Nefrectomia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Ablação por Radiofrequência/efeitos adversos , Idoso , Carcinoma de Células Renais/mortalidade , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Estimativa de Kaplan-Meier , Neoplasias Renais/mortalidade , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/prevenção & controle , Estadiamento de Neoplasias , Nefrectomia/métodos , Complicações Pós-Operatórias/etiologia , Ablação por Radiofrequência/métodos , Reoperação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA